Circuit Breakers, Magnetic, Unsealed or Panel Seal, Trip-Free, General Specification For
FSC 5925

This specification covers the requirements and test procedures for single and multipole, trip-free, unsealed, magnetic circuit breakers with current ratings of 0.2 amperes to 100 amperes inclusive, up to and including 240 volts, 400 Hertz, 480 volts, 60 Hertz alternating current (ac) and 125 volts direct current (dc). These circuit breakers may also include auxiliary contacts for monitoring circuits. A voltage sensitive pole is also available in a four pole device. Panel seal mounts are available in 0.2 amperes through 50 amperes.


Points of contact:
Circuit Protection Group
Phone: 614-692-0556, 0548
Email: CircuitProtect@dla.mil

Document Downloads
MIL-PRF-55629Acrobat file
Circuit Breakers, Magnetic, Unsealed or Panel Seal, Trip-Free, General Specification For
Revision: D, Dated: 8 February 2008
File name: prf55629.pdf, File size: 166 kb
MIL-PRF-55629D Supplement 1Acrobat file
List of MIL-PRF-55629 Associated Specifications
Dated: 8 January 2008
File name: prf55629sup1.pdf, File size: 19 kb
MIL-PRF-55629 EP StudyAcrobat file
The Use of Pure Tin Finishes in MIL-PRF-39019 and MIL-PRF-55629 Circuit Breakers.
Dated: 8 January 2008
File name: prf55629EPStudy.pdf, File size: 21 kb
MIL-PRF-55629/1GAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Single Pole, (0.2 to 100 Amperes)
Dated: 10 March 2010
File name: prf55629ss1.pdf, File size: 104 kb
MIL-PRF-55629/2GAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Single Pole, Auxiliary Contacts (0.2 to 50 Amperes)
Dated: 10 March 2010
File name: prf55629ss2.pdf, File size: 120 kb
MIL-PRF-55629/3GAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Double Pole, (0.2 to 50 Amperes)
Dated: 10 March 2010
File name: prf55629ss3.pdf, File size: 123 kb
MIL-PRF-55629/4GAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Double Pole, Auxilary Contacts, (0.2 to 50 Amperes)
Dated: 10 March 2010
File name: prf55629ss4.pdf, File size: 129 kb
MIL-PRF-55629/5GAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Three Pole, (0.2 to 50 Amperes)
Dated: 10 March 2010
File name: prf55629ss5.pdf, File size: 122 kb
MIL-PRF-55629/6GAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Three Pole, Auxiliary Contacts, (0.2 to 50 Amperes)
Dated: 10 March 2010
File name: prf55629ss6.pdf, File size: 136 kb
MIL-PRF-55629/7EAcrobat file
Circuit Breakers, Magnetic, Low-Power Unsealed, Trip-Free, Series Trip, Single Pole, (0.2 to 30 Amperes)
Dated: 10 March 2010
File name: prf55629ss7.pdf, File size: 85 kb
MIL-PRF-55629/8FAcrobat file
Circuit Breakers, Magnetic, Low-Power, Unsealed, Trip-Free, Series Trip, Single Pole, Auxiliary Contacts (0.2 to 30 Amperes)
Dated: 10 March 2010
File name: prf55629ss8.pdf, File size: 84 kb
MIL-PRF-55629/9EAcrobat file
Circuit Breakers, Magnetic, Low-Power, Unsealed, Trip-Free, Series Trip, Double Pole (0.2 to 30 Amperes)
Dated: 10 March 2010
File name: prf55629ss9.pdf, File size: 92 kb
MIL-PRF-55629/10EAcrobat file
Circuit Breakers, Magnetic, Low-Power, Unsealed, Trip-Free, Series Trip, Double Pole, Auxiliary Contacts (0.2 to 30 Amperes)
Dated: 10 March 2010
File name: prf55629ss10.pdf, File size: 98 kb
MIL-PRF-55629/11EAcrobat file
Circuit Breakers, Magnetic, Low-Power, Unsealed Trip-Free, Series Trip, Three Pole (0.2 to 30 Amperes)
Dated: 10 March 2010
File name: prf55629ss11.pdf, File size: 98 kb
MIL-PRF-55629/12FAcrobat file
Circuit Breakers, Magnetic, Low-Power, Unsealed, Trip-Free, Series Trip, Three Pole, Auxiliary Contacts (0.2 to 30 Amperes)
Dated: 10 March 2010
File name: prf55629ss12.pdf, File size: 99 kb
MIL-C-55629/13CAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Single Pole, Front Mounted, Auxiliary Contacts, (1 to 100 Amperes)
Dated: 3 April 2010
File name: mil55629ss13.pdf, File size: 51 kb
MIL-C-55629/14CAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Single Pole, Back Mounted, (1 to 100 Amperes)
Dated: 3 April 2010
File name: mil55629ss14.pdf, File size: 50 kb
MIL-C-55629/15CAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Two Pole, Front Mounted, Auxiliary Contacts, (1 to 100 Amperes)
Dated: 3 April 2010
File name: mil55629ss15.pdf, File size: 63 kb
MIL-C-55629/16CAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Two Pole, Back Mounted, (1 to 100 Amperes)
Dated: 3 April 2010
File name: mil55629ss16.pdf, File size: 62 kb
MIL-C-55629/17CAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Three Pole, Front Mounted, Auxiliary Contacts, (1 to 100 Amperes)
Dated: 3 April 2010
File name: mil55629ss17.pdf, File size: 70 kb
MIL-C-55629/18CAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Three Pole, Back Mounted, (1 to 100 Amperes)
Dated: 3 April 2010
File name: mil55629ss18.pdf, File size: 67 kb
MIL-C-55629/19DAcrobat file
Circuit Breakers, Magnetic, Unsealed, Trip-Free, Four Pole, Front Mounted, Auxiliary Contacts, (1 to 100 Amperes)
Dated: 3 April 2010
File name: mil55629ss19.pdf, File size: 79 kb
MIL-PRF-55629/20GAcrobat file
Circuit Breakers, Magnetic, Panel Seal, Trip-Free, Series Trip, Single Pole (0.2 to 30 Amperes)
Dated: 10 March 2010
File name: prf55629ss20.pdf, File size: 93 kb
MIL-PRF-55629/21GAcrobat file
Circuit Breakers, Magnetic, Panel Seal, Trip-Free, Series Trip, Double Pole (0.2 to 30 Amperes)
Dated: 10 March 2010
File name: prf55629ss21.pdf, File size: 106 kb
MIL-PRF-55629/22GAcrobat file
Circuit Breakers, Magnetic, Panel Seal, Trip-Free, Series Trip, Three Pole (0.2 to 30 Amperes)
Dated: 10 March 2010
File name: prf55629ss22.pdf, File size: 109 kb

Related Items
QPL-55629
Qualified Products List
Search for other documents with FSC 5925


Back to index.Document Index
New search.Document Search

Comments or questions: VaWebTeam@dla.milSend email

Site Help Privacy & Security     External Links     Accessibility     Viewers
Date of Last Update: 15 May 2003